Pulse counter electronic
Codix 541
|
|
Pulse counter, double-channel with 6 types of counter inputs, freely scalable.
The Codix 541 is a voltage powered pulse counter / position display with count input modes: count direction, difference, addition, quadrature (phase discriminator) x1, x2 and x4, for fast and slow count pulses, with 6-digit LED display for NPN, PNP input signals.Mechanical | |
---|---|
Model | electronic |
Function |
Position displays without limit values |
Dimension 1 |
96 x 48 mm | 92 x 45 mm |
Protection level |
IP65 |
Working temperature | -20 °C ... +65 °C |
Weight | 150 g |
Reset |
electronic |
(1) Front panel size | Panel cut-out
Electrical | |
---|---|
Power supply |
100...240 (± 10%) V AC 10...30 V DC |
Signal input |
NPN PNP |
Powerful
- Fast count input – input frequency max. 60 kHz.
- Robust housing – IP65 protected.
- Very bright LED display, 14 mm high.
- Position, difference, adding or count direction detection:
- programmable for positive (PNP) or OV (NPN) switching input pulses.
- fast count input with an input frequency of max. 60 kHz, can be damped to 30 Hz for mechanical contacts.
- Short start-up time – detects input pulses just 16 msec after being switched on => no pulses are lost with a simultaneous motor start-up.
User-friendly and universal
- Large keys – can also be operated when wearing gloves.
- Simple uniform menu-driven programming and operation – possible to enter the programming also during operation with a confirmation prompt.
- Individually programmable scaling: Multiplication and division factor (0.0001…99.9999), to display corresponding engineering units, e.g. position in 1/10 mm or packaging units.
- 4 different count input modes: 2-channel count input for detecting count direction, difference or adding mode, quadrature with x1, x2 or x4 evaluation.
- Freely programmable setpoint.
- AC or DC power supply with sensor power supply.
- As an alternative to the HTL inputs, devices are available with a 4 ... 30 V DC input level, for use as parallel displays to PLCs.
- Optional output - as zero signal.