Process controllers for standard signals electronic
573T
|
|
573T LCD touch multifunction preset counters
The process controller with 2 analog inputs can be used in both single channel mode as well as in dual channel. In dual channel mode, all arithmetic operations are available for displaying the sum total, difference, ratio or the product. Inputs and outputs can be scaled separately.Can be used as a simple process signal converter, process controller (ON/OFF controller) or for complex measuring tasks, where the relationship between two values, one to the other, must be monitored, calculated or further processed in a higher-level controller.
Mechanical | |
---|---|
Model | Dual-function device electronic |
Functions |
Process controllers for standard signals Standard signal measuring devices Process displays for standard signals |
Dimension 1 |
96 x 48 mm | 92 x 45 mm |
Protection level |
IP20 IP65 |
Working temperature | -20 °C ... +60 °C |
Weight | 200 g |
Reset |
electronic |
(1) Front panel size | Panel cut-out
Electrical | |
---|---|
Power supply |
115 V AC 230 V AC 18...30 V DC |
Signal input |
Analog ±10 V Analog 0...20 mA Analog 4–20 mA PNP |
Signal output |
Analog ±10 V Analog 0...20 mA Analog 4–20 mA RS232 RS485 2 x Relais 4 x PNP |
Interfaces |
Modbus IO-Link Printer CR/LF Drivecom DIN ISO 1745 |
573T LCD touch multifunction preset counters
Properties- 2 separate freely scalable analog inputs ±10 V and 0/4 to 20 mA, resolution 16 bit.
- Tare function, the device can be set to 0 at any input voltage.
- Programmable linearization With up to 24 support points, input via keyboard or by means of the teach function.
- Mean value measurement programmable from 2 to 16 measuring cycles, with strongly fluctuating input signals.
- Simple programming by entering the desired display value for a defined input signal.
- Fast measuring rate of 25 ms per channel alternating.
- RS232 or RS485 serial interface for reading and writing data.
Benefits
- Up to 3 display values in one device, display A, display B, calculated display from A and B.
- AC and DC supply voltage in one device.
- Simple plain text programming via touch display and separate tare or teach function.
- Can be used as a simple process converter, process control unit (2 point controllers) or for complex measuring tasks in which 2 values are to be monitored, calculated or further processed in a higher-level control system.
- Mathematical linking of the measured values of input A and B. The result can also be multiplied, divided or added to an offset value to obtain the desired display value.
- Analog output 0/4 to 20 mA, or ±10 V.
- 4 fast PNP switching outputs, 50 ms, with switching hysteresis, step or drag preset.
- Programmable display update.